Contact us today for any questions you may have and we’ll help you out.
Disconnect the programming cable and exit RSLogix 5000.ĬompactLogix (Serial versions) User Manualīuckles-Smith is an electrical distributor with multiple stocking locations throughout Northern California and the San Francisco Bay Area. You can change the mode by clicking the controller mode dropdown in the upper left corner. AB RSLINX CLASSIC USB CONNECTION 1769 L33 SOFTWARE
The software may ask if you want to change to “Run” mode, which is the mode where the controller is scanning its I/O, executing the program logic, and then enabling outputs and sending any data or messages. You will now be online with the controller, which means you are looking at what the controller is doing in real time, and you can make on-line edits, change values, etc. The controller will upload the file to the PC, and save it in the directory you selected. Enter a name for the project file, and select where you would like to save it. RSLogix will respond "Create project file 'xxxxx.ACD' and upload?". Type in a file name and select where to save the file. Let’s assume you are backing up the file because you do not have an offline file. RSLogix will ask you to find the corresponding offline project file. The "Connected to Upload" window will appear. If you ever forget, just remember “Download = Danger!” meaning, make sure you want to overwrite what is currently in the controller! Important note: In the PLC world, “Upload” means transfer from the controller to the PC, and “Download” means transfer the program from the PC to the controller. On the right hand side, several grayed-out options should now become available. The controller should appear under the DF-1 driver. AB RSLINX CLASSIC USB CONNECTION 1769 L33 DRIVER
Expand the driver by clicking the plus sign to the left of the driver.Select the DF1 driver you configured earlier ( AB_DF1-1).The RSLinx Who Active browser will pop up.Go to "Communications" and select "Who Active".
AB RSLINX CLASSIC USB CONNECTION 1769 L33 SERIAL
If unsuccessful, check your serial and USB cable connections, and make sure you are using the correct COM port number assigned to the USB-Serial adapter.If successful, close window and minimize RSLinx.Under the “Device” drop down, select the “Logix 5550 / CompactLogix” setting.Under the “Comm Port” drop down menu, select the COM port that corresponds to the one assigned to the USB-Serial Adapter (e.g.The "Configure RS232 DF1 Devices" window will pop up.You can give the driver a name, or just select “OK” to use the default name (typically AB_DF1-1).Under Available Driver Types, select “RS232 DF1 devices” and click the “add new” button.Go to Communications > Configure Drivers.Launch RSLinx Classic, usually Start > All Programs > Rockwell Software > RSLinx > RSLinx Classic.
Expand the section, note the COM port number after the Serial to USB converter. Scroll down to the "Ports (COM & LPT)" section.
Go to "Device Manager", under your computer’s Control Panel. Insert USB end of the USB-Serial adapter cable into an open USB port on your computer. Connect the 9-pin serial cable to the 9-pin port on controller, and the 9-pin port on USB-Serial Adapter. RSLinx Classic Lite or better, included with RSLogix/Studio 5000
If no serial port on PC, USB-Serial Adapter 9300-USBS, Quickstart GuideĬompactLogix: RSLogix/Studio 5000 Mini edition or betterĬontrolLogix: RSLogix/Studio 5000 Service edition or Models Coveredĩ-Pin Serial Programming cable, typically 1747-CP3 Stay tuned for Part II where we will connect to Ethernet and USB controllers.
AB RSLINX CLASSIC USB CONNECTION 1769 L33 HOW TO
Today we will cover the first three steps on how to backup your Allen-Bradley Logix Controller Program to your PC. Your guide to backup your Logix Controller Program